<LOGO>
FM Transmitter Measurement Report
Created: 2023-06-08 04-42-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 79 dBuV RIRE &
Pilot RDS Phase Difference
7.1 kHz 4.0 kHz 61 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 66 kHz 17139 0,0292
Modulation Power
Limit Measuring Tolerance
8,0 dBr 1,0 dBr
MIN AVE MAX % above 9,0 dBr
5,1 dBr 6,27 dBr 7,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 4:42, 8.06.2023
RT
"RIRE : JEAN-JACQUES GOLD "
AF EON
87.8, 88.7, 94.4, 95.4, 95.5, 96.2, 101.5 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (79 dBuV) Max at: 66 kHz MIN: 11 kHz % above 75 kHz: 0,0292 Acquired: 2023/06/08 4:41:35 Total samples: 17139 Equivalent time: 0:14:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,7 dBr MIN: 5,1 dBr AVE: 6,27 dBr % above 9,0 dBr: 0,0 Last value: 6,9 dBr (2023/06/08 4:41:34) Station: 101.50 MHz, signal: 5/5 (79 dBuV) 04:30 04:32 04:34 04:36 04:38 04:40 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality